McNab Model AP-IJ Water Conductance Monitor
Indicator / Controller System

A02-49 ap-ij cabinet.jpg (104599 bytes)

Stainless Steel enclosure withstands harsh environment without the added cost of accessory. Meets need for marine shock and vibration.

Print Version

Features:

  • 117 or 220 VAC 48/62 Hz
  • Range: 0 to 20,000 micromhos
  • Marine Approved - Robust design
  • Flame-proof 316 Stainless Enclosure
  • Automatic Electrical Self Zero
  • Either grounded cell or balanced cell
    input
  • 0-1 mA remote output standard
  • Linear signal mode available as 4-20 mA
    isolated output
  • Wall mounting
  • Door hinged and gasketed
  • Internal adjustable controls
  • Meets USPHS control locations requirements
  • Cabinet Size: 8 1/4"H x 7 1/8" W x 5 5/8"D
  • Extra thick PC Board - 1/16"
  • 120,000 MTBF

Description 

The Aqua Purometer IJ (AP-IJ) Water Monitor Indicator and Control System is used to monitor the purity of water by means of electricity. It may be installed at water tanks or piping systems and can be used to monitor a great variety of contaminants, detection, water treatment, RO water or separation processes involving dissolved solids. 

Conductance values reflecting water purity level are linearly indicated on the panel meter. In general, the higher the reading the less pure the water. The scale on the panel meter may be changed to indicate chemical content (ppm) or any other special option. An adjustable limit of allowable impurity is included in the electronic monitor circuit (alarm set point). The alarm point is set to any desired meter level. If the water impurity level rises above this preset limit, the controller relay in the monitor circuit is energized, causing the ALARM indicator on the panel to light and/or a bell (where included) to sound.

A02-49 ap-ij board.jpg (98015 bytes)

Connections

A02-49 ap-ij connections.jpg (301607 bytes)

Typical Cell

A04-73 image.jpg (418520 bytes)

Specifications

Model AP-IJ
Units of Measure Microsiemans, mhos, pp
Range 0-20, 200, 2,000, 20,000
Input Signal Unbalanced, balanced
Mode Linear
Meter/Type 2.5" Analog
Weight 6 lbs.
Cell/Instrument Valve Provided with quotation
Temperature: Normal/Max. (typ) Depends on design of cell
Pressure: Normal/Max. (typ) 65, 100 & 150 psi, Depends on design of cell
Pipe Connection Size ¾, 1" or 1¼ NPT
Wetted Material Depends on design of cell, typical gold electrodes
Cable Length (typ) 6 feet typical
Calibration Cell test resistor
Accessory Cell (1) Semi-flush mounting kit (PN 18479) (2) Cell test module used for verification of correct operation (3) Drip shield (PN 18241) (4) 100 ft. cell cable (PN 22063-1001) (5) Cable strain relief (39131-7) (6) Alarm bell 220 VAC 50 Hz (by others)
Ranges Available 0-2, 20, 200, 2,000 or 20,000
Controller  Internal control adjusts set point, which is displayed on meter during adjustment procedure. Outputs: (suitable for two-wire automatic valve AC line voltage energized normally open and normally closed for solenoid dump valve). Non-energized normally open, and non-energized normally closed.
Relay  Sealed. Contacts rated at 5 amps (resistive). Fail-safe mode.
Weight 2.75 kg (6 lbs.) panel only
Maximum Cell Temperature To 120°C (250°C)
Diameter of Cell ¾, 1 or 1 ¼ NPT
Instruction Book PN 515

Probes

View probe specifications for the AP-I family of McNab analyzers.